A full-size fridge nameplate in the catalog is 150W. It cycles. Hours below use the catalog average range of 60W and 80W, not 150W times 24 hours.
Hours use usable watt-hours: nameplate Wh x 0.80 depth of discharge x 0.90 inverter efficiency. The 1.25 sizing buffer is for buying a new battery. It is not used for hours of a station you already own.
Catalog note: cycles about 8-12 hours a day, average 60-80W. This page does not claim how many days food stays cold.
Only power stations Field Authority has signed appear here. Catalog SKUs without a lock-file row stay off this table.
Compressor start can exceed nameplate. This table uses continuous watts only. No unsigned surge number.
| Station | Wh | Inverter W | Usable Wh | Runtime |
|---|---|---|---|---|
| EcoFlow DELTA 3 Ultra | 3072 | 3600 | 2211.8 | 36 hours |
| EcoFlow DELTA 3 Ultra Plus | 3072 | 3600 | 2211.8 | 36 hours |
| EcoFlow DELTA 3 Max | 2048 | 2400 | 1474.6 | 24 hours |
| EcoFlow DELTA 3 Max Plus | 2048 | 3000 | 1474.6 | 24 hours |
| EcoFlow DELTA Pro 3 | 4096 | 4000 | 2949.1 | 49 hours |
| Goal Zero Yeti 1000 Core | 983 | 1200 | 707.8 | 11 hours |
| Goal Zero Yeti 500X | 497 | 300 | 357.8 | 5.9 hours |
| Bluetti EP500 | 5120 | 2000 | 3686.4 | 61 hours |
| Jackery Explorer 500 v2 | 512 | 500 | 368.6 | 6.1 hours |
| EcoFlow DELTA 3 1500 | 1536 | 1800 | 1105.9 | 18 hours |
| EcoFlow DELTA 3 Classic | 1024 | 1800 | 737.3 | 12 hours |
| BLUETTI Elite 100 V2 | 1024 | 1800 | 737.3 | 12 hours |
| BLUETTI Elite 200 V2 | 2073.6 | 2600 | 1493.0 | 24 hours |
| Goal Zero Yeti 1500 LFP | 1505 | 2000 | 1083.6 | 18 hours |
| Jackery HomePower 3000 | 3072 | 3600 | 2211.8 | 36 hours |
| PECRON F3000LFP | 3072 | 3600 | 2211.8 | 36 hours |
Open this load in the runtime calculator
| Station | Wh | Inverter W | Usable Wh | Runtime |
|---|---|---|---|---|
| EcoFlow DELTA 3 Ultra | 3072 | 3600 | 2211.8 | 27 hours |
| EcoFlow DELTA 3 Ultra Plus | 3072 | 3600 | 2211.8 | 27 hours |
| EcoFlow DELTA 3 Max | 2048 | 2400 | 1474.6 | 18 hours |
| EcoFlow DELTA 3 Max Plus | 2048 | 3000 | 1474.6 | 18 hours |
| EcoFlow DELTA Pro 3 | 4096 | 4000 | 2949.1 | 36 hours |
| Goal Zero Yeti 1000 Core | 983 | 1200 | 707.8 | 8.8 hours |
| Goal Zero Yeti 500X | 497 | 300 | 357.8 | 4.4 hours |
| Bluetti EP500 | 5120 | 2000 | 3686.4 | 46 hours |
| Jackery Explorer 500 v2 | 512 | 500 | 368.6 | 4.6 hours |
| EcoFlow DELTA 3 1500 | 1536 | 1800 | 1105.9 | 13 hours |
| EcoFlow DELTA 3 Classic | 1024 | 1800 | 737.3 | 9.2 hours |
| BLUETTI Elite 100 V2 | 1024 | 1800 | 737.3 | 9.2 hours |
| BLUETTI Elite 200 V2 | 2073.6 | 2600 | 1493.0 | 18 hours |
| Goal Zero Yeti 1500 LFP | 1505 | 2000 | 1083.6 | 13 hours |
| Jackery HomePower 3000 | 3072 | 3600 | 2211.8 | 27 hours |
| PECRON F3000LFP | 3072 | 3600 | 2211.8 | 27 hours |
Open this load in the runtime calculator
Usable watt-hours are 3072 x 0.80 x 0.90. At a 60W cycling average that is 36 hours. At 80W that is 27 hours. Nameplate 150W is not the all-day average.
If continuous inverter watts are at least 150W, the running load clears the gate. Hours are still short on a small battery. Check the table for the signed SKU.
No. This is battery hours at a cycling wattage. Food hold is a different problem and is not on this page.
A fridge compressor cycles. The catalog average is 60-80W. Using 150W all day understates hours.