How long will a power station run a sump pump?

Catalog sump pump is 500W. A sump runs in bursts when the pit fills. Hours below are at 500W continuous.

Hours use usable watt-hours: nameplate Wh x 0.80 depth of discharge x 0.90 inverter efficiency. The 1.25 sizing buffer is for buying a new battery. It is not used for hours of a station you already own.

Catalog default is 4 hours. Storm duty can be more. Size the battery for the wet hours, not a dry basement.

Only power stations with manufacturer watt-hour and inverter numbers appear here. Catalog SKUs without those numbers stay off this table.

A compressor or pump can pull more watts for a moment than the running watts in this table. This table has no start-up number. Hours here do not mean the motor will start. On the runtime calculator, type the start-up watts from the nameplate. Leave that box blank if the label does not list them. This page will not guess.

Sump pump 500W

StationWhInverter WUsable WhRuntime
EcoFlow DELTA 3 Ultra307236002211.84.4 hours
EcoFlow DELTA 3 Ultra Plus307236002211.84.4 hours
EcoFlow DELTA 3 Max204824001474.62.9 hours
EcoFlow DELTA 3 Max Plus204830001474.62.9 hours
EcoFlow DELTA Pro 3409640002949.15.8 hours
Goal Zero Yeti 1000 Core9831200707.81.4 hours
Goal Zero Yeti 500X497300357.8Cannot run. Inverter 300W, load 500W.
Bluetti EP500512020003686.47.3 hours
Jackery Explorer 500 v2512500368.644 minutes
EcoFlow DELTA 3 1500153618001105.92.2 hours
EcoFlow DELTA 3 Classic10241800737.31.4 hours
BLUETTI Elite 100 V210241800737.31.4 hours
BLUETTI Elite 200 V22073.626001493.02.9 hours
Goal Zero Yeti 1500 LFP150520001083.62.1 hours
Jackery HomePower 3000307236002211.84.4 hours
PECRON F3000LFP307236002211.84.4 hours
BLUETTI FridgePower201618001451.52.9 hours
Jackery Explorer 1500 Ultra153618001105.92.2 hours

Open this load in the runtime calculator

Frequently Asked Questions

How long will a 3072Wh station run a sump pump?

Usable watt-hours are 3072 x 0.80 x 0.90. At 500W that is 4.4 hours of pump-on time.

Will a small station run a sump?

If continuous inverter watts are at least 500W, the running load clears this table. A 300W inverter cannot. Start-up watts can be higher than 500W, and they are not on this page. Hours on a small battery are short in a long rain.

Should the sump be on a battery during a storm?

If the pit fills when the grid is down, yes. This table is hours at 500W, not a promise the pit stays dry.