Catalog well water pump is 750W. A well pump runs in short cycles when you open a tap. Hours below are at 750W continuous.
Hours use usable watt-hours: nameplate Wh x 0.80 depth of discharge x 0.90 inverter efficiency. The 1.25 sizing buffer is for buying a new battery. It is not used for hours of a station you already own.
Catalog default is 2 hours a day of pump time. That is not a full day of household water. Check the inverter gate. Start current can exceed nameplate.
Only power stations Field Authority has signed appear here. Catalog SKUs without a lock-file row stay off this table.
Compressor start can exceed nameplate. This table uses continuous watts only. No unsigned surge number.
| Station | Wh | Inverter W | Usable Wh | Runtime |
|---|---|---|---|---|
| EcoFlow DELTA 3 Ultra | 3072 | 3600 | 2211.8 | 2.9 hours |
| EcoFlow DELTA 3 Ultra Plus | 3072 | 3600 | 2211.8 | 2.9 hours |
| EcoFlow DELTA 3 Max | 2048 | 2400 | 1474.6 | 1.9 hours |
| EcoFlow DELTA 3 Max Plus | 2048 | 3000 | 1474.6 | 1.9 hours |
| EcoFlow DELTA Pro 3 | 4096 | 4000 | 2949.1 | 3.9 hours |
| Goal Zero Yeti 1000 Core | 983 | 1200 | 707.8 | 56 minutes |
| Goal Zero Yeti 500X | 497 | 300 | 357.8 | Cannot run. Inverter 300W, load 750W. |
| Bluetti EP500 | 5120 | 2000 | 3686.4 | 4.9 hours |
| Jackery Explorer 500 v2 | 512 | 500 | 368.6 | Cannot run. Inverter 500W, load 750W. |
| EcoFlow DELTA 3 1500 | 1536 | 1800 | 1105.9 | 1.4 hours |
| EcoFlow DELTA 3 Classic | 1024 | 1800 | 737.3 | 58 minutes |
| BLUETTI Elite 100 V2 | 1024 | 1800 | 737.3 | 58 minutes |
| BLUETTI Elite 200 V2 | 2073.6 | 2600 | 1493.0 | 1.9 hours |
| Goal Zero Yeti 1500 LFP | 1505 | 2000 | 1083.6 | 1.4 hours |
| Jackery HomePower 3000 | 3072 | 3600 | 2211.8 | 2.9 hours |
| PECRON F3000LFP | 3072 | 3600 | 2211.8 | 2.9 hours |
Open this load in the runtime calculator
Not if the inverter is below 750W continuous. The table marks those rows cannot run.
If the inverter is at least 750W, usable watt-hours are 3072 x 0.80 x 0.90, then divide by 750. That is about 2.9 hours of pump-on time.
Maybe, if the pump only runs when you draw water. This page is pump-on hours, not gallons delivered. Pressure tanks and well depth change the real duty.